13. Inspection/Maintenance
13.2.2 Replacement Procedure IX-NNN2515H/3515H, IX-NNC2515H/3515H
(1) Remove the six low-head cap screws (6 pcs) and remove the rear panel (base).
(2) Remove the batteries from the battery holder.
(3) Remove the batteries from the extension cables from the battery connectors, and connect new batteries.
After removing the old batteries, quickly connect new batteries (roughly within 5 minutes x
number of batteries).
If new batteries are not connected for a longer period, the rotation data will be lost and an
absolute reset will become necessary.
Replace batteries one axis at a time. If the batteries for all axes are replaced at once, the work
may not be completed within the specified time.
(4) Install the batteries into the battery holder.
(5) Affix the rear panel (base) using the six low-head cap screws [1].
When installing the rear panel (base), be careful not to pinch the cables inside.
Be careful not to leave out the seal washer.
Caution
Battery (for axis 1)
Battery connector 3
(for axis 3)
Battery
(for axis 3)
Battery connector 2
(for axis 2)
Battery (for axis 2)
Battery connector 4
(for axis 4)
Battery (for axis 4)
[1] 6 - M4 x 8
(low-head cap screw)
Rear panel
(base)
Battery connector 1
(for axis 1)