Iai-america RCS-C Manuel d'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 119
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
54
(7) Acceleration only MAX
(ACC MAX)
Select the specified acceleration or maximum acceleration by entering
“0” or “1.”
The default value is “0.”
0: Specified acceleration --- The value entered in (4) becomes the
actual acceleration/deceleration.
1: Maximum acceleration --- The maximum acceleration set according
to the load is used.
The deceleration conforms to the value
entered in (4).
(7) Acceleration only MAX = 0 (7) Acceleration only MAX = 1
Note: As a rough guide, enable the acceleration only MAX setting when the actual loading capacity is no
more than one-third of the rated loading capacity.
Check the rated loading capacity of your actuator by referring to the supplied specification list of
supported actuators.
Acceleration/deceleration
set in (4)
Acceleration/deceleration
set in (4)
Maximum acceleration
according to the load
Speed
Speed
Moving distance
Moving distance
Vue de la page 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 118 119

Commentaires sur ces manuels

Pas de commentaire