Iai-america IX-NNC3515 Manuel d'utilisateur Page 43

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 42
37
6. Inspection/Maintenance
(5) Tighten the two cap screws (M4 x 8) [4] to affix the cap.
(6) Tighten the bellows clamp using a Phillips screwdriver.
(7) Turn the cap to confirm that the bellows rotate smoothly.
z Check the marking tubes to prevent improper connections.
z Be careful not to bend the air tubes.
z Be careful not to pinch the cables.
z Place the wires neatly in the upper space without letting them rest on top of one another. Do not
forcibly tighten the screws with the panel still floating.
z Check if the connectors are fully inserted.
z If the cover is removed, absolute reset must be performed again for the rotational axis and vertical
axis. (See 6.4, “Absolute Reset Procedure.”)
[4]
Phillips screwdriver
Turn the cap to check if the
bellows are not twisted.
Caution
Cap
Vue de la page 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 75 76

Commentaires sur ces manuels

Pas de commentaire