Part 3 Controller Data Structure
INTELLIGENT ACTUATOR
1.10 Axis Specification
Axes can b
e specified based on axis number or axis pattern.
(1) Axis numbers and how axes are stated
Each of multiple axes is stated as follows:
Axis number How axis is stated
1 Axis 1
2 Axis 2
3 Axis 3
4 Axis 4
The axis numbers stated above can also be expressed using symbols.
Use axis number if you wish to specify only one of multiple axes.
x Commands that use axis specification based on axis number
BASE, PPUT, PGET, AXST, PASE, PCHZ, ACHZ, PARG