Part 4 Commands
PAXS (Read axis pattern)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Output
(Output, flag)
Operand 1 Operand 2
Optional Optional PAXS
Variable
number
Position
number
CP
Store the axis pattern at the position specified in operand 2 to the variable specified in
operand 1.
Read the axis pattern at position 98 to variable 1.
If the position is given as follows, “3” (binary 0011) will be
Assign 101 to variable 2.
Read the axis pattern at the content of variable 2 (position
101) to the content of variable 1 (variable 3).
If the point is given as follows, “8” (binary 1000) will be
The table below shows different positions and corresponding values stored in a variable.
0 0 1 1 = 2 + 1 = 3
0 1 0 1 = 4 + 1 = 5
0
1 0 0 0 = 8