339
Appendix
(In the panel window, the three digits after “E” indicate an error number.)
Description, action, etc.
The parameter number is invalid.
The variable number is invalid.
The string number is invalid.
String-variable data count specification error
The specified number of string variables exceeds the area, etc.
String-variable delimiter non-detection error
Delimiter cannot be detected in the string variable.
String-variable copy size over error
The copy size of string variable is too large.
Character count non-detection error during string processing
The character-string length is not defined in string processing. Execute a string
processing command after defining the length with a SLEN command.
Character-string length error during string processing
The character-string length used in string processing is invalid. Check the value
of character-string length defined by a SLEN command.
Blank area shortage error with source-symbol storage table
There is not enough area to store the source symbols. Check the number of
times source symbol can be used.
Definitions are not found for the symbols used in the program steps.
C48 SIO-message continuous conversion error The transmitted SIO message does not match the message format or contains
invalid data. Check the transmitted message.
The SIO is being used by other interpreter task.
Serial channel 1 opened to the user is not opened in the target task. Open the
channel using an OPEN command first.
Delimiter non-definition error
An end character is not defined. Set an end character using a SCHA command
first.
SIO1 invalid usage OPEN error
The usage of serial channel 1 opened to the user does not match the
parameter. Check “I/O parameter No. 90, Usage of SIO channel opened to
Program data/source symbol checksum error
The flash ROM data has been destroyed.
Symbol definition table checksum error
The flash ROM data has been destroyed.
Point data checksum error
The flash ROM data has been destroyed.
Backup SRAM data destruction error
The backup SRAM data has been destroyed. Check the battery.
Invalid flash-ROM SEL global data/error list error
The SEL global data/error lists in the flash ROM are invalid.
Flash-ROM SEL global data/error list duplication error
The SEL global data/error lists in the flash ROM are duplicated.
C55 Flash-ROM erase count over error for SEL global data/error lists The number of time the flash ROM containing SEL global data/error lists can be
Timing limit over error (Flash ROM erase)
Error erasing the flash ROM
Flash-ROM verify error (Flash ROM erase)
Error erasing the flash ROM