(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
C3B
Parameter number error
The parameter number is invalid.
C3C
Variable number error
The variable number is invalid.
C3D
String number error
The string number is invalid.
C3E
String-variable data count specification error
The specified number of string variables exceeds the area, etc.
C40
String-variable delimiter non-detection error
Delimiter cannot be detected in the string variable.
C41
String-variable copy size over error
The copy size of string variable is too large.
C42
Character count non-detection error during string processing
The character-string length is not defined in string processing. Execute a string
processing command after defining the length with a SLEN command.
C43
Character-string length error during string processing
The character-string length used in string processing is invalid. Check the value
of character-string length defined by a SLEN command.
C46
Blank area shortage error with source-symbol storage table
There is not enough area to store the source symbols. Check the number of
times source symbol can be used.
C47
Symbol search error
Definitions are not found for the symbols used in the program steps.
C48 SIO-message continuous conversion error The transmitted SIO message does not match the message format or contains
invalid data. Check the transmitted message.
C49
SEL-SIO in-use error
The SIO is being used by other interpreter task.
C4A
SCIF unopen error
Serial channel 1 opened to the user is not opened in the target task. Open the
channel using an OPEN command first.
C4B
Delimiter non-definition error
An end character is not defined. Set an end character using a SCHA command
first.
C4E
SIO1 invalid usage OPEN error
The usage of serial channel 1 opened to the user does not match the
parameter. Check “I/O parameter No. 90, Usage of SIO channel opened to
user.”
C4F
Program data/source symbol checksum error
The flash ROM data has been destroyed.
C50
Symbol definition table checksum error
The flash ROM data has been destroyed.
C51
Point data checksum error
The flash ROM data has been destroyed.
C52
Backup SRAM data destruction error
The backup SRAM data has been destroyed. Check the battery.
C53
Invalid flash-ROM SEL global data/error list error
The SEL global data/error lists in the flash ROM are invalid.
C54
Flash-ROM SEL global data/error list duplication error
The SEL global data/error lists in the flash ROM are duplicated.
C55 Flash-ROM erase count over error for SEL global data/error lists The number of time the flash ROM containing SEL global data/error lists can be
erased was exceeded.
C56
Timing limit over error (Flash ROM erase)
Error erasing the flash ROM
C57
Flash-ROM verify error (Flash ROM erase)
Error erasing the flash ROM