347
Appendix
(In the panel window, the three digits after “E” indicate an error number.)
Description, action, etc.
D81 Parameter error during calculation of valid target data An invalid parameter value was detected during calculation of valid target data.
Check axis-specific parameter Nos. 7, 8, 138, etc.
D82 Simple interference check zone output-number specification error A value other than an output port/global flag number (0 is allowed) may have
been input, or the specified number may be already used as a system output
number via the I/O parameter for output function selection.
Simple interference check zone number error
The simple interference check zone number is invalid.
SCIF send-buffer overflow error
The SCIF send buffer overflowed.
SCI send-buffer overflow error
The SCI send buffer overflowed.
SCIF receive-buffer overflow error
The SCIF receive buffer overflowed. Excessive data was received from outside.
SCI receive-buffer overflow error
The SCI receive buffer overflowed. Excessive data was received from the slave.
Receive timeout error (Slave communication)
Response from the slave cannot be recognized.
SCI overrun error (Slave communication)
Communication failure. Check for noise, circuit failure and slave card.
SCI framing error (Slave communication)
Communication failure. Check for noise, shorting, circuit failure and slave card.
SCI parity error (Slave communication)
Communication failure. Check for noise, shorting, circuit failure and slave card.
SCI CRC error (Slave communication)
The CRC in the message is invalid.
SCIF communication mode error
The communication mode is invalid.
SCI communication mode error
The communication mode is invalid.
SIO-bridge SCIF send-queue overflow error
The send queue overflowed.
SIO-bridge SCI send-queue overflow error
The send queue overflowed.
SCI receive-data-register full wait timeout error
Communication failure. Check for noise, shorting, circuit failure and slave card.
Communication failure. Check for noise, shorting, circuit failure and slave card.
Program end confirmation timeout error
The program cannot be ended.
I/O-processing-program start logic error
The I/O-processing-program start logic is invalid.
The WAIT factor is invalid.
The WAIT logic is invalid.
Point-data valid address error
Point-data valid address is not set.
The source data is invalid.
E1D Unaffected output number error The unaffected output number is invalid. A value other than an output port
number (“0” is acceptable) may be input in I/O parameter Nos. 70 to 73.