(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
E1F I/O assignment parameter error A value other than an I/O port number (“-1” is acceptable) or other than an I/O
head port number + [multiple of 8] may be input in I/O parameter Nos. 2 to 9, or a
value other than a [multiple of 8] may be input in I/O parameter Nos. 14 to 17.
E20
I/O assignment duplication error
I/O assignments are duplicated. Check I/O parameter Nos. 2 to 9 and 14 to 17 and
the I/O slot card type (number of I/Os), etc.
E21
I/O assignment count over error
The I/O assignments exceed the specified range. Check I/O parameter Nos. 2 to 9
and 14 to 17 and the I/O slot card type (number of I/Os).
E22
Header error (Slave communication)
The header in the message received from the slave card is invalid.
E23
Card ID error (Slave communication)
The card ID in the message received from the slave card is invalid.
E24
Response type error (Slave communication)
The response type in the message received from the slave card is invalid.
E25
Command type error (Slave communication)
The command type of the transmitting command is invalid.
E26
Target type error
The target type is invalid.
E27
No target error
Target (driver card, I/O card, encoder or other slave card) is not installed.
E29
EEPROM error (EWEN/EWDS not permitted)
EEPROM access error (when writing)
E2A
Read compare mismatch error during EEPROM write
EEPROM access error (when writing)
E2B
Abnormal response error when sending EEPROM information
acquisition command
An abnormal response was received when a slave-EEPROM information
acquisition command was sent.
E2C Maximum receive size over error when sending EEPROM
information acquisition command
The maximum receive size exceeds the limit value when a slave-EEPROM
information acquisition command is sent.
E2D
Receive-data checksum error when sending EEPROM
information acquisition command
The checksum of receive data is invalid when a slave-EEPROM information
acquisition command is sent.
E2E
No required power stage error
The required power stage is not installed for the valid axes.
E2F
No required regenerative resistance error
The required regenerative resistance is not installed for the valid axes.
E30
No required motor-drive power error
The required motor-drive power is not installed for the valid axes.
E31
No standard I/O slot error
Standard I/O unit is not installed.
E32
No control power error
Control power unit is not installed.
E33
Slave response logic error
The slave response logic is invalid.
E34
Slave block number out of range
The slave block number is out of range.
E37
Slave data setting prohibited
Setting of slave data is prohibited.
E38
Faulty slave EEPROM
The slave EEPROM is faulty.
E39
No encoder EEPROM error
The encoder is not equipped with EEPROM.
E3A
Absolute encoder error
Absolute encoder is specified illegally. (Check axis-specific parameter No. 38.)
E3C
Undefined slave-command error code detected
An undefined slave-command error code was detected.
E3D SEL program/point/parameter flash ROM status error Data is not written to the flash ROM correctly or written in an old, incompatible