Iai-america XSEL-KE Manuel d'utilisateur Page 205

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 424
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 204
190
Part 4 Commands
1.17 Zone
z
WZNA (Wait for zone ON, with AND)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional WZNA
Zone
number
Axis
pattern
CP
[Function] Wait for the zone status of all axes (AND) specified by the axis pattern in operand 2 to
become ON (inside zone) with respect to the zone specified in operand 1.
(Note 1) The zone status of axes not yet completing home return will remain OFF (outside zone).
(Note 2) A maximum of four areas can be set as zoQHVIRUHDFKD[LV³$[LVVSHFLILFSDUDPHWHU1RV
WR´
1RWH =RQHRXWSXWFDQEHVSHFLILHGXVLQJ³$[LVVSHFLILFSDUDPHWHU1RVDQG´
irrespective of this command.
[Example 1] WZNA 1 11 If the parameters are set as follows, the program
will wait until the zone status of axes 1 and 2
becomes ON (inside the shaded area shown in the
diagram below).
[Example 2] The axis pattern can be specified indirectly using a variable.
When the command in [Example 1] is rephrased based on indirect specification using
a variable:
11 (binary) o 3 (decimal)
LET 5 3 Assign 3 to variable 5.
WZNA 1 *5
Axis 1 Axis 2
³$[LVVSHFLILFSDUDPHWHU1R=RQHPD[´
(Value is set in units of 0.001 mm)
300000 200000
³$[LVVSHFLILFSDUDPHWHU1R=RQHPLQ´
(Value is set in units of 0.001 mm)
150000 100000
The program will proceed to the next step if both axes
1 and 2 are inside the shaded area.
Axis 2
Axis 1
200
100
150 300
Vue de la page 204