Iai-america XSEL-KE Manuel d'utilisateur Page 246

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 424
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 245
231
Part 4 Commands
x The arch-motion Z-axis will come down after a rise-process command value is output. Therefore, the
operation may follow the locus in Fig. 5 given in the aforementioned explanation of PACH command,
depending on the settings of arch-trigger points and Z point. In this case, change the arch triggers and
Z point to increase the operation efficiency.
x As for the arch-trigger end-point data, if there is any valid axis data other than the data of the arch-
motion Z-axis, then operation will be started/ended foUWKHDSSOLFDEOHD[HVLQWKHVDPHPDQQHU²EXW
above the arch triggers.
x If arch-trigger composition is set, any valid axes other than those set in the end-point data or the arch-
motion Z-axis will also be operated as long as data is available for such axes. In this case, operation of
the applicable axes will also be started/ended above the arch triggers.