Iai-america XSEL-QX Manuel d'utilisateur Page 133

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 558
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 132
109
Part 3 Controller Data Structure
2. When the System Memory Backup Battery is Not Used
2.1 Controller without Increased Memory Size
Other parameter No. 20 = 0 (System memory backup battery not installed)
The programs, parameters, symbols and positions are read from the flash memory at restart. The data in
the main CPU memory will remain the same as the original data before edit unless the edited data are
written to the flash memory. The controller always operates in accordance with the data in the main CPU
memory (excluding the parameters).
Note: SEL global data cannot be retained if the backup battery is not installed.
Data edited on the PC
or teaching pendant
Data will be retained while the power is
on and cleared upon reset
Data will be retained even after the
power is turned off
PC
software,
TP
Transfer
Transfer
Transfer
Main CPU memory
Programs
Parameters (other than
slave parameters)
Symbols
Positions
Coordinate system data
Slave card parameters
(driver card
parameters)
Slave card parameters
(encoder parameters)
Write to flash memory
Write to flash memory
Transfer upon reset
Transfer upon reset
Transfer upon reset
Transfer upon reset
Transfer upon reset
Transfer
Main CPU flash memory
Slave card memory
Slave card memory
Slave card parameters
(driver card parameters
(cannot be changed))
SEL global data (flags,
variables, strings)
Error lists
Vue de la page 132