(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
CCB Arch start-point/trigger reversing error The coordinates of start point and start-point arch trigger are reversed during arch
motion operation.
CCC Arch end-point/trigger reversing error The coordinates of end point and end-point arch trigger are reversed during arch
motion operation.
CCD Drive-source cutoff axis use error An attempt was made to use an axis whose drive source is cut off.
CCE Error axis use error An attempt was made to use an axis currently generating an error.
CCF Palletizing reference-point/valid-axis mismatch error The PX/PY(/PZ)-axes set by PASE/PCHZ are not valid in the axis pattern of the
reference-point data set by PAST.