Iai-america XSEL-QX Manuel d'utilisateur Page 196

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 558
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 195
172
Part 4 Commands
1.9 Task Management
z EXIT (End program)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional EXIT Prohibited Prohibited CP
[Function] End the program.
If the last step has been reached without encountering any EXIT command, the program
will return to the beginning.
(Note) Status at program end
x Output ports
Retained
x Local flags
Cleared
x Local variables
Cleared
x Current values
Retained
x Global flags
Retained
x Global variables
Retained
[Example 1] :
:
EXIT End the program.
Vue de la page 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 557 558

Commentaires sur ces manuels

Pas de commentaire