503
Appendix
(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
C1C Unused-LD detection error An attempt was made to execute a command based on multiple LD condition that
has been saved, without using it in extension condition AB or OB.
C1F Input-condition CND shortage error The necessary input condition is not found when an extension condition is used.
C21 Input-condition use error with input-condition prohibited command Input-condition prohibited commands prohibit the use of input conditions.
C22 Invalid command position error with input-condition prohibited
command
A command for which input condition is prohibited cannot be included in an input
condition nest.
C23 Invalid operand error Program step error. The necessary operand data is invalid.
C24 Operand type error Program step error. The operand data type is invalid.
C25 Actuator control declaration error The setting of actuator control declaration command is invalid.
C26 Timer setting-range over error The timer setting is invalid.
C27 Timeout setting-range over error during wait The timeout setting is invalid.
C28 Tick count setting-range error The Tick count setting is invalid.
C29 DIV command divisor 0 error “0” was specified as the divisor in the DIV command.
C2A SQR command range error The operand value in the SQR command is invalid. Input a value larger than “0” as
data in a SQR command.
C2B BCD display digit range error The specified number of BCD display digits is invalid. Specify a value between 1
and 8.
C2C Program number error An undefined supported program number was specified.
C2D Step number error The step number is invalid.
C2E Blank step shortage error There are not enough blank steps to save step data. Provide enough blank steps
needed to save step data.
C2F Axis number error The axis number is invalid.
C30 Axis pattern error The axis pattern is invalid.
C32 Operating-axis addition error during command execution An operating axis for point data was added during continuous point movement or
push-motion movement calculation.
C33 Base axis number error The base axis number is invalid.
C34 Zone number error The zone number is invalid. Cartesian axis only.
C35 Point number error The point number is invalid.
C36 I/O port/flag number error The I/O port/flag number is invalid.
C37 Flag number error The flag number is invalid.
C38 Tag number error The tag number is invalid.
C39 Subroutine number error The subroutine number is invalid.
C3A User-open channel number error The channel number of the channel opened to the user is invalid.
C3B Parameter number error The parameter number is invalid.
C3C Variable number error The variable number is invalid.