429
Appendix
No. Parameter name Default value
(Reference)
Input range
Unit
Remarks
24 I/O setting bit pattern 1
(Related to global
specifications)
10000H 0H ~
FFFFFFFFH
Bits 0 to 3: RDY OUT function selection (System IO)
(0: SYSRDY (Software = PIO trigger
program can be run) and hardware is
normal (emergency stop has not be
actuated and hardware error is not
present)
1: Error of operation-cancellation level
or higher is not present
2: Error of cold-start level or higher is
not present
Bits 4 to 7: RDY LED function selection
(0: Program can be run
1: Error of operation-cancellation level
or higher is not present
2: Error of cold-start level or higher is
not present)
Bits 8 to 11: DET (MELT) (melted drive-source cutoff
relay) signal enable selection (0: Disable,
1: Enable)
Bits 12 to 15: Drive-source cutoff relay DET (MELT)
error level (when low voltage cannot be
checked)
(0: Cold start, 1: Message)
Bits 16 to 19: Drive-source cutoff relay DET (MELT)
error level (when low voltage cannot be
checked)
(0: Cold start, 1: Message)
25 I/O setting bit pattern 2
(Related to global
specifications)
0H 0H ~
FFFFFFFFH
Bits 0 to 3: For future extension
Bits 4 to 7: For future extension
26~
28
(For extension) 0
29 Physical output port
number for drive-source
cutoff (SDN) notification
0 0 ~ 599 Turn the output port OFF when the drive source is cut
off
(* Important: This is only a software notification output)
(Invalid if “0” is set)
* Note: Enter a hexadecimal value if the tool (PC
software or TP) is of a version where input areas
are indicated by “h” notation.