Vue de la page 458
435
Appendix
I/O Parameters
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
100 Used by the SIO system
(SP3) (extended)
28100010H 0H ~
FFFFFFFFH
Bits 28 to 31: Baud rate type (0: 9.6, 1: 19.2, 2: 38.4,
3: 57.6, 4: 76.8, 5: 115.2 kbps)
Bits 24 to 27: Data length (7 or 8)
Bits 20 to 23: Stop bit length (1 or 2)
Bits 16 to 19: Parity type (0: None, 1: Odd, 2: Even)
Bits 12 to 15: Communication mode (0: RS232C, 1:
RS422, 2: RS485) * Only “0” can be
selected for board channels other than
Nos. 1 and 2
Bits 8 to 11: Receive operation type (0: RS485 =
Forcibly enable receive immediately
after send, RS232C/RS422 = Forcibly
enable receive immediately before
send
1: Do not forcibly enable receive at
send)
Bits 4 to 7: Board channel assignment number (1:
D-sub upper, 2: D-sub lower, 3: Flat
connector upper, 4: Flat connector
lower)
Bits 0 to 3: Expanded I/O slot assignment number
(Expanded I/O slots 1 to 3 from the slot
next to the standard IO (I/O1) slot. * “0”
means no slots are used)
101 (For SIO system (SP3)
extension (extension))
0 0H ~
FFFFFFFFH
102 Used by the SIO system
(SP4) (extended)
28100020H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
103 (For SIO system (SP4)
extension (extension))
0 0H ~
FFFFFFFFH
104 Used by the SIO system
(SP5) (extended)
28100010H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
105 (For SIO system (SP5)
extension (extension))
0 0H ~
FFFFFFFFH
106 Used by the SIO system
(SP6) (extended)
28100020H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
107 (For SIO system (SP6)
extension (extension))
0 0H ~
FFFFFFFFH
108 Used by the SIO system
(SP7) (extended)
28100010H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
109 (For SIO system (SP7)
extension (extension))
0 0H ~
FFFFFFFFH
110 Used by the SIO system
(SP8) (extended)
28100020H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
111 (For SIO system (SP8)
extension (extension))
0 0H ~
FFFFFFFFH
112 Used by the SIO system
(SP9) (extended)
28100030H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
113 (For SIO system (SP9)
extension (extension))
0 0H ~
FFFFFFFFH
114 Used by the SIO system
(SP10) (extended)
28100040H 0H ~
FFFFFFFFH
(Same as with I/O parameter No. 100)
115 (For SIO system (SP10)
extension (extension))
0 0H ~
FFFFFFFFH
116~
119
(For extension) 0
120 Network attribute 1 1H 0H ~
FFFFFFFFH
Bits 0 to 3: CC-Link remote register area
H/L byte swap selection (0: Do not
swap, 1: Swap)
* The number of used ports and
number of occupied stations in I/O
parameter Nos. 14 and 15 must
match.
121 Network attribute 2 0 0H ~
FFFFFFFFH
122 Network attribute 3 0 0H ~
FFFFFFFFH