Appendix
Description Action Parameter setting Manipulation/operation
Want to output signal when all valid
linear movement axes are at their
home.
Output port No. 304 can be set as a
signal indicating that all valid linear
movement axes are at their home.
Note: Do not use a HOME command
when the controller is of the absolute
specification.
I/O parameter No. 50 = 1 Output port No. 304 will turn ON when
all valid linear movement axes are at
their home.
Want to output signal when all valid
linear movement axes have completed
home return.
Output port No. 304 can be set as a
signal indicating that all valid linear
movement axes have completed home
return.
I/O parameter No. 50 = 2 Output port No. 304 will turn ON when
all valid linear movement axes have
completed home return.
Want to release brake using an
external input signal.
A general-purpose input port can be set
as a brake forced-release input
(dedicated input). Set a desired input
port number in the applicable
parameter.
Set a desired input port number in the
I/O parameter corresponding to the
target axis number.
Correspondence of brake-releasing
axis number and parameter number:
Axis 3: I/O parameter No. 64
Axis 4: I/O parameter No. 65
Axis 5: I/O parameter No. 66
Axis 6: I/O parameter No. 67
Setting example) To set input port No.
12 as the brake forced-release input for
axis 3, set as follows:
I/O parameter No. 64 = 12
Brake will be forcibly released when the
applicable port turns ON.
m Brake of axis 3 will be forcibly
released when input port No. 12 turns
ON.
Want to retain output status while
emergency-stop signal is input or the
safety gate is open.
Minimum and maximum port numbers
indicating the output ports you wish to
retain can be set.
I/O parameter No. 70 = Output port
number MIN
I/O parameter No. 71 = Output port
number MAX
Setting example) To retain output ports
from port Nos. 303 through 315, set as
follows:
I/O parameter No. 70 = 303
I/O parameter No. 71 = 315
m The status of output port Nos. 305
through 315 will be retained while
emergency-stop signal is input or the
safety gate is open.