(In the panel window, the three digits after “E” indicate an error number.)
Error No. Error name Description, action, etc.
6A1
UBM data configuration change error Data configuration in the user-data backup memory was changed. Initialize the
memory.
6A2
UBM size overflow error Settings exceeded the user-data backup memory size.
x Too many RC gateway position points
6A3
UBM use function over error The user-data backup memory is used by too many functions. Limit the applicable
functions to 8 or less.
6A4
RC axis position data setting error Invalid RC axis position data setting.
Example:
x The value of other parameter No. 501 is greater than the value of other parameter
No. 503.
x An axis outside the range of other parameter No. 502 is enabled.
6A5 RC axis position data enable address error An attempt was made to access an invalid RC axis position data.
6A6
RC gateway DPRAM access error (main) A DPRAM access violation error occurred between the main and SIO board. (Main
CPU side)
6A7
RC gateway DPRAM access error (mounted SIO) A DPRAM access violation error occurred between the main and SIO board.
(Mounted SIO)
6A8
RC gateway major failure error The mounted SIO experienced a major failure.
Example:
x All enabled RC axes have detached (due to cable disconnection, broken wire, etc.)
x The power-supply switch on the main CPU board is receiving 0 V.
x The mounted SIO could not acquire the DPRAM access right for a specified period
or longer.
x The mounted SIC generated a CPU error or other major error.
6A9 RC gateway link initialization timeout error A timeout occurred in the initialization of a RC axis link.
6AA RC gateway DPRAM access right timeout error The DPRAM access right could not be acquired for a specified period or longer.
6AB RC gateway command issuance timeout error A gateway command cannot be issued.
6AC RC axis control job logic error Invalid RC axis control job logic.
6AD RC axis control command logic error Invalid RC axis control logic.
6AE Mounted SIO operation mode specification error An invalid operation mode was set for the mounted SIO.
6AF Mounted SIO RC gateway function selection parameter error Invalid RC gateway parameter setting.
6B0 Mounted SIO RC gateway logic error Invalid RC gateway initialization logic.
6B1 RC gateway unsupported error (mounted SIO) Invalid RC gateway system configuration.
6B2 RC gateway I/O assignment parameter error Invalid assignment setting in the PLC through mode.
6B3 RC axis control job timeout error No response was returned from the RC axis for a specified period.
6B4 RC gateway emergency-stop mismatch error The emergency stop status of the X-SEL control does not match the emergency
stop status of the RC controller. Check the connection.
6B5 Belt breakage error The drive belt in the actuator broke.